8. Various settings
8.1. Setting items
The time and date are held even if processed to default (factory reset).
Setting items
Display
Default Selectable from Note
Angle feature Ang OFF OFF/ ON
Measurement mode SEL MODE-M MODE-M/ MODE-T
Unit of torque USEL N
m
N
m/ kgf
cm/ kgf
m/
lbf
in/ lbf
ft
Lower limit torque Lo 0 0
Maximum capacity
Higher limit torque HI 0 0
Maximum capacity More than lower limit torque
Trigger torque Trg 0 0/ 5%
100% of capacity
Double tightening
detection angle
An_d 0 0
999
Enable when set on the "MODE-T" and
trigger torque
Lower limit angle An_L 0 0
999
Enable when set on the trigger torque.
More than double tightening detection angle
Higher limit angle An_H 0 0
999
Enable when set on the trigger torque.
More than double tightening detection angle
and lower limit angle
Tightening direction tUrn CW CW/ CCW/ BotH
Auto reset timer Ar 0.0 0.0/ 0.1
5.0
NG data processing ng NG_MAN NG_MAN/ NGAUTO
Buzzer bU ON ON/ OFF
Auto power off PoFF 3MIN 3MIN/ 10MIN/ 30MIN/ OFF
Communication mode do BT BT/ PC
Baud rate bps 9600 2400/ 4800/ 9600/ 19200 For "PC" communication mode
Data length dL 8bit 7bit/ 8bit For "PC" communication mode
Parity P
None None/ Odd/ Even For "PC" communication mode
Communication format dCn M-3 M-3/ M3+ID
Default setting dFLt DFT-N DFT-N/ DFT-Y
Time rtC1 - -
Date rtC2 - -