EasyManua.ls Logo

Tokheim ProGauge MAGLINK LX - Connecting the RF Receiver (for XMT-SI-RF)

Tokheim ProGauge MAGLINK LX
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAGLINK LX
Installation Manual
| Connections
Rev. 09,
– April 2016
Page 14 of 24
6.3
Connecting the RF Receiver (for XMT-SI-RF)
The image below shows how to connect your console to an RF Receiver:
The receiver connects directly to connector CN7 without going through the intrinsically safe barrier.
In this case the barrier remains unused.
Connection
Specifications
CN7
Not used - Terminal 5
White (-0 V) - Terminal 4
Blue (RS485B) - Terminal 3
Brown (RS485A) - Terminal 2
Red (+ 12V) - Terminal 1
For proper connections of the receiver, you must refer to the installation manual of the RF Receiver
(Section on electrical connections).