6.4
Interface to relay diagram of connectors
The following image shows the connectors of a Maglink LX slave console:
The following table lists the console connectors:
Connector
Specifications
Connector
Specifications
CN1
CANBUS Conn
for DVD probes
CN8
Power input (13 VDC)
1
CANH
1
+12 V
2
CANL
2
GND
3
GND
3
Not used
CN2
Relay 1 connector
CN10
Digital input connector (Activated with a
positive voltage)-DEEP 3 OFF
1
Normally Closed
2
Common
1
GND (activated with a positive
voltage)
3
Normally Open
CN3
Relay 2 connector
2
Input 1
1
Normally Closed
3
Input 2
2
Common
4
Input 3
3
Normally Open
5
Input 4
CN4
Relay 3 connector
6
Input 5
1
Normally Closed
7
Input 6
2
Common
CN10
Digital input connector (Activated with a
positive voltage)-DEEP 3 ON
3
Normally Open
CN5
Relay 4 connector
1
GND (activated with a positive
voltage)
1
Normally Closed
2
Common
2
Not Enabled
3
Normally Open
3
+12 VDC (theft protection)
CN7
RS485 port
4
Not Enabled
1
Red (+12 V)
5
Not Enabled
2
Brown (RS485A)
6
Not Enabled
3
Blu (RS485B)
7
Not Enabled
4
White (
0 V)
CN11 Main board connector
5
Not used