MAGLINK LX
Installation Manual
| Installation
Rev. 09,
– April 2016
Page 8 of 24
5
I
NSTALLATION
5.1
Preliminary warnings.
IMPORTANT: The MAGLINK LX console is not explosion-proof
IMPORTANT: Explosions and fires can cause damage or even death
IMPORTANT: Flammable vapours when mixed with air can cause an explosion. Dangerous
areas can occur from the presence of gases or vapours
IMPORTANT: Do not install the console in a hazardous area
IMPORTANT: Only use fuses of 250 V - 1 A for input power
5.2
Place of installation
You must consider that the console was not designed to withstand vibrations and extreme climatic
conditions (High and low temperatures, humidity, etc.) which can damage the electrical circuits when
selecting the console installation site.
ATTENTION: Install the console in a place that is protected from moisture and water splashes
IMPORTANT: The console must be installed in safe area
5.3
Electrical connection
The following table shows the steps necessary for the electrical connection to a 220 VAC:
Step Description
1 Turn off all power switches on the electrical panel
2 Connect the electrical panel and the console using the appropriate connectors
3
For power connections, use a single-phase cable, a section of which is not less than 1.5 mm
2
and
one which is adequately protected. The power cord must comply with the standards IEC 60227
and IEC 60245. The cable supplied with the console already complies with regulations.
4
Make sure the power plug is connected to the ground and protected against short circuits and
power surges
5
The power cord must be easily recognizable and accessible as it also has the function of removing
power