EasyManua.ls Logo

Tomy SX-700E - Page 15

Tomy SX-700E
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ー14ー
[Exhaust speed setting] keys
Allow the set exhaust speed value to
be changed by pressing these keys.
Changing operation is permissible during
the temperature and pressure reduction
process only when liquid sterilizing is
selected.
[Cooling fan setting] key
Allows the cooling fan setting to be
changed by pressing this key. Changing
operation is allowed during the
temperature and pressure reduction
process when liquid sterilizing is selected.
Key for the external temperature sensor
of articles to be sterilized
Used when the optional external
temperature sensor of articles to be
sterilized is connected.
[Timer] key
Allows timer to be selected and the waiting
time to be set and checked by pressing
this key.
[Function] key
Allows the temperature releasing the lid
interlock, warming time, and display form
to be set and checked by pressing this key.
[Temperature setting] keys
Allow the set temperature for the
sterilizing or heating process to be
changed by pressing these keys.
[Time setting] keys
Allow the set time for the sterilizing or
heating process to be changed by pressing
these keys.
[Warming/timer setting] keys
Allow the set temperature for the
warming process to be changed by
pressing these keys. Allow the waiting
time to be changed by pressing these keys
following the [timer] key.
[Check] key
Allows the current temperature to be
checked by pressing this key during
preparation.Allows the set conditions to
be checked by pressing this key during
operation.
[Start] key
Allows operation to start by pressing this
key.
[Stop] key
Allows operation to be stopped by
pressing this key.
[Sterilize /Liquid] key
Allows the liquid sterilizing course to
be selected by pressing this key during
preparation.
[Sterilize] key
Allows the sterilizing course to be selected
by pressing this key during preparation.
[Sterilize-Warm] key
Allows the sterilizing-warming course to
be selected by pressing this key during
preparation.
[Heat-Warm] key
Allows the heating-warming course to
be selected by pressing this key during
preparation.
[Memory] key
Allows the displayed course setting to
be memorized by holding down this key
during preparation.
Allows the memorized courses to be
selected by pressing this key during
preparation.

Other manuals for Tomy SX-700E

Related product manuals