Explains safety symbols used in the manual, including warning and caution indicators.
Provides essential safety warnings and cautions for operating the centrifuge safely.
Details the expected service life of rotors and buckets in terms of years and cycles.
Describes the fundamental working principles of the high-speed refrigerated microcentrifuge.
Identifies and labels the main components and parts of the centrifuge unit.
Provides instructions and precautions for safely moving and installing the centrifuge unit.
Details the procedure for safely turning the centrifuge's main power switch on and off.
Explains the correct method for opening and closing the centrifuge's chamber lid.
Provides step-by-step instructions for securely mounting and dismounting the rotor.
Guides on how to prepare sample tubes correctly for centrifugation, including safety precautions.
Covers the essential steps and precautions for properly loading samples into the rotor.
Specific instructions and compatibility for loading samples using the rack-in-rotor system.
Details on proper sample loading procedures for angle rotors.
Instructions and safety checks for loading samples into swing-out rotors.
Explains how to set critical operating parameters like temperature, speed, and time.
Outlines the final checks and procedure for starting the centrifuge operation.
Describes the process of ending a centrifugation run and stopping the unit.
Details the steps for safely removing sample tubes after the run has ended.
How to monitor current operating conditions like temperature, speed, and time during a run.
Instructions on modifying operating parameters while the centrifuge is running.
Explains how to perform short, quick centrifuge runs using the 'Flash' key.
How to switch the display from speed (rpm) to Relative Centrifugal Force (RCF).
Describes the memory function for storing and recalling frequently used operating parameters.
Details the power-saving ECO mode and how to activate/deactivate it.
Allows setting the rotational radius for RCF calculations, essential for accurate speed adjustments.
Configures the adaptive speed setting for the soft brake deceleration mode.
Enables selection of different patterns for short centrifuge runs using the Flash key.
Sets the specific speed to be used when operating in the Flash mode.
Allows customization of the buzzer sound type at the end of a run.
Sets the duration for which the buzzer will sound after a run.
Configures the time limit for the chamber lid remaining open before an alarm.
Adjusts the delay before the centrifuge enters the ECO power-saving mode.
Enables viewing the cumulative total run time of the instrument.
Allows checking the total number of centrifugation runs performed.
Provides procedures for cleaning and disinfecting the exterior and interior of the centrifuge.
Instructions for cleaning and disinfecting rotors, buckets, and racks.
Outlines the monthly cleaning and inspection tasks to maintain the centrifuge.
Lists common symptoms of malfunction and provides corresponding solutions and actions.
A reference table detailing error codes, their causes, and actions to resolve them.
Provides contact details for assistance, service, and repair inquiries.
Explains the manual procedure to open the chamber lid during a power outage or malfunction.
Lists the acceleration and deceleration times for various rotors used with the centrifuge.
Details the cooling performance of the centrifuge with different rotors at specified speeds.
Shows which rotors are compatible with each centrifuge model (MX-307, MX-207, MX-107).
Provides detailed specifications for rotors and lists compatible tubes for each.
A comprehensive summary of the technical specifications for all three centrifuge models.