10 SETTING ATMOSPHERIC CORRECTION
10-58
8.4 儀器系統誤差補償之校正
1) 垂直軸誤差 (X,Y tilt sensor offset) 2) 視準軸誤差
3) 垂直角指標差 4) 橫軸誤差
上述之誤差項目可經由儀器內部軟體之計算值自動補償之。
或者也藉由儀器內部軟體之指引,經由操作儀器而消除該誤差。1)
操作步驟 按鍵
顯示
c 將儀器架設於穩定之平地上。
d 按主畫面之 [F5] (ADJ)
[F5]
Adjustmen
F1 V0/Axis (Measurement)
F2 V0/Axis (Constant list)
F3 Date Time
F4 Instrumnet constant
e 按 [F1]
[F1]
[V0/Axis Adjustments]
ERROR CORRECTION
(A)Tilt,V0 init,Collimation
(B) H Axis
(A)COLLIMATION
f 照準 A (在水平± 3° 間) 以正鏡觀測之(FACE(1)).
照準
A
(正鏡)
FACE 1
LEVEL ±0
V : 88° 40 '20"
SKIP SET
g 按 [F6](SET)* 1)
右邊範例是以正鏡連續觀測五次(FACE 1)
[F6]
FACE 1
LEVEL ±0
V : 89° 55' 50"
SKIP SET
h 然後將儀器轉至倒鏡 (FACE(2)).
Turn
telescope
FACE 2
LEVEL ±0
V : 270° 04 '20"
SKIP SET
/ 0
/ 5
0 / 5