10 SETTING ATMOSPHERIC CORRECTION
10-60
8.5 顯示補償值及切換補償功能之開 /
[例:關閉補償功能]
操作步驟 按鍵 顯示
c 由主畫面中按 [F5]
[F5]
Adjustment
F1 V0/Axis (Measurement)
F2 V0/Axis (Constant list)
F3 Date Time
F4 Instrumnet constant
d [F2] 顯示補償值。
[F2]
Vco: -1°57'12"
Hco: -0°00'20"
HAx: -0°00'20"
EXIT ON OFF
e [F6](OFF)
[F6]
Vco: -1°57'12"
Hco:
HAx:
EXIT ON OFF
f [F1](EXIT) 回主畫面。
[F1]