Using the MINTER
P/N 7010-0626 www.topconpositioning.com
4-3
Reset Key
Pressing the reset key for about one second causes:
a hard reset of the receiver.
the receiver to leave Zero Power Mode and return to
Normal Mode.
NOTICE
NOTICE
Only use this procedure if the receiver does not respond
to commands or does not charge the internal batteries (is
in Zero Power Mode).
FN Key and Record LED
Table 4-1 on page 4-5 summarizes FN key functions and REC
LED statuses. See “FN Key Mode parameter” on page 2-23 for
information on setting FN key modes.
Pressing the FN key for less than one second switches the
receiver between different information modes (normal and
extended information), or between static and dynamic post-
processing modes, depending on the receiver's
configuration.
During the first second of pressing the FN key, the REC
LED is orange.
Pressing the FN key for more than one and less than five
seconds will start/stop data recording.
During data recording the REC LED is green.
If the REC LED is red, the receiver has run out of memory,
has a hardware problem, or contains an improper OAF (see
“Option Authorization File (OAF)” on page 1-20 for more
information on OAFs).