EasyManua.ls Logo

Topcon LN-100 - Calculation and Assessment of Accuracy

Topcon LN-100
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
7. CHECK
Measurement results recording table:
Calculation
Obtain the distance error (ED) and the vertical error (EZ) from the following formulas:
Assessment
Confirm that the distance error (ED) and the vertical error (EZ) fall within the following ranges:
Distance error
-6 (mm) < ED < +6 (mm)
Vertical error
-11.6 (mm) < EZ < +11.6 (mm)
If the error falls out of the range, contact your local dealer.
Instrument point Target X [m] Y [m] Z [m]
1
a
X
1,a :
Y
1,a :
Z
1,a :
b
X
1,b :
Y
1,b :
Z
1,b :
2
a
X
2,a :
Y
2,a :
Z
2,a :
b
X
2,b :
Y
2,b :
Z
2,b :
D
1
X
1 a,
X
1 b,
()
2
Y
1 a,
Y
1 b,
()
2
+=
D
2
X
2 a,
X
2 b,
()
2
Y
2 a,
Y
2 b,
()
2
+=
Z
1
Z
1 a,
Z
1 b,
=
Z
2
Z
2 a,
Z
2 b,
=
ED mm[]
D
1
D
2
()
2
------------------------
1000×=
EZ mm[] Z
2
Z
1
()1000×=

Related product manuals