Checks and repairs on electrical components
46
Connect a multimeter to the two contacts (F) of the solenoid valve.
Measure the electrical resistance of the coil.
The resistance has to be 1100 Ω ± 10 %.
If the resistance is outside this range, the solenoid valve is defective.
Replace the defective solenoid valve, see from page 47.