4 Instructions for Use TORMAX iMotion 1301/1301.S / 1302.KI /1401 T-1305 en
1.4 Explanation of the Symbols
Warning (signal word)
Source of hazard (designates a possibly hazardous situation)
Possible consequences of non-observance
• Measures for averting danger.
Text which is highlighted in grey MUST be observed to ensure that the system operates perfectly.
Failure to observe these sections can cause damage to equipment.
Functions marked with this symbol are the factory setting. However, they can be reprogrammed
by a specialist.
Optional components which are not present in all systems.
1.5 Technical Data
Drive type Electromechanical swing door operator with AC permanent magnet
synchronous motor
Control system Control unit MCU32
Mains connection 1 x 230 V AC, 10 – 16 A
1 x 115 V AC, 15 – 20 A, 50 – 60 Hz
Power consumption iMotion 1301 5 … 250 W
iMotion 1301.S 12 … 330 W
iMotion 1302.KI 6 … 205 W
iMotion 1401 6 … 250 W
Sensor supply iMotion 1301, 1302.KI 24 V DC + 0,5 / –1,5 V, max. 18W / 0,75 A,
in battery operation min. 16,5 V
iMotion 1301.S, 1401 24 V DC + 0,5 / –1,5 V, max. 36 W / 1,5 A,
in battery operation min. 16,5 V
Protective class, drive iMotion 1301, 1301.S, IP 20
1302.KI
iMotion 1401 IP 68
Protective class, iMotion 1401 IP 55
control box
Ambient temperature –20 °C to +50 °C
Fuse iMotion 1301, 1302.KI 8 AT (TÜV) / 5 AT (UL)
iMotion 1301.S, 1401 8 AT
Weight drive iMotion 1301, 1301.S 14,5 kg
iMotion 1302.KI 13,9 kg
iMotion 1401 39 kg Control unit: 3,9 kg
Noise emission level < 70 db (A)
Electromagnetic IEC 61000-6-2, IEC 61000-6-3
compatibility (EMV)
Service life Tested to 1’000’000 cycles