22
1
2
Figure 21
1. Agitation control valve 2. Pressure gauge
For agitation to work, the pump must be on and the engine
must be running above an idle. If you stop the sprayer and
need agitation on, place the range selector in the Neutral
position, set the parking brake, press the accelerator pedal
to the floor, and turn the neutral engine speed control on.
Pressure Gauge
The pressure gauge is located to the right of the tank
(Fig. 21). This gauge shows the pressure of the fluid in the
system in psi and kPa.
Pump
The pump is located near the front of the tank on the right
side (Fig. 22).
2
1
Figure 22
1. Pump 2. Grease fitting
Tank Drain Handle
The tank drain handle is located on top of the tank
(Fig. 23). Pull the handle out to drain the tank.
Important Pull the handle gently out until it stops. Do
not pull too hard or you may damage it.
1
Figure 23
1. Tank drain handle
Tank Cover
The tank cover is located in the center of the top of the tank
(Fig. 24). To open it, turn off the engine, then turn the front
half of the cover to the left and swing it open. You can
remove the strainer inside for cleaning. To seal the tank,
close the cover and rotate the front half toward the right.
1
2
Figure 24
1. Tank cover 2. Anti-siphon fill receptacle
Anti-siphon Fill Receptacle
To the front of the tank cover is a hose receptacle with a
threaded fitting, a 90 degree barbed fitting, and a short hose
which you can direct toward the tank opening (Fig. 24).
This receptacle allows you to connect a water hose to it and
fill the tank with water without contaminating the hose with
the chemicals in the tank.
Important Do not lengthen the hose to allow contact
with the tank fluids.