56
SOLENOID VALVE (Contd)
5. Position valve body subassembly and coil
subassembly together.
MAINTENANCE
6. Replace lower diaphragm housing (14).
Secure coil assembly (1), body subassembly and
lower diaphragm housing (14) using four screws
(15). Care must be exercised to uniformly tighten
the retaining screws (15).
7. Replace electrical connections. There is no
positive or negative terminal.