EasyManua.ls Logo

Toro 74534TE GrandStand - Sound Pressure; Sound Power; Vibration Level for Model 74534 TE; Vibration Level for Model 74536 TE

Toro 74534TE GrandStand
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SlopeOperation
Allslopesandrampsrequireextracaution.Ifyoufeeluneasy
onaslope,donotmowit.
Removeobstaclessuchasrocks,treelimbs,etc.fromthe
mowingarea.
Watchforholes,rutsorbumps.Tallgrasscanhide
obstacles.
Usecautionneardrop-offs,ditches,orembankments.
Themachinecouldsuddenlyturnoverifawheelgoes
overtheedgeofaclifforditch,orifanedgecavesin.
Useextracarewithgrasscatchersorotherattachments.
Thesecanchangethestabilityofthemachine.
Keepallmovementonslopesslowandgradual.
Donotmakesuddenchangesinspeedordirection.
Mowslopessidetoside.
Donotmowslopesgreaterthan15degrees.
Service
Donotstorethemachineorafuelcontainerinsidewhere
thereisanopename,suchasnearawaterheateror
furnace.
Keepthenutsandboltstight,especiallythe
blade-attachmentbolts.
Neverremoveortamperwithsafetydevices.Checktheir
properoperationregularly.Neverdoanythingtointerfere
withtheintendedfunctionofasafetydeviceortoreduce
theprotectionprovidedbyasafetydevice.
Tobestprotectyourinvestmentandmaintainoptimal
performanceofyourToroequipment,countonToro
genuineparts.Whenitcomestoreliability,Torodelivers
replacementpartsdesignedtotheexactengineering
specicationsofourequipment.Forpeaceofmind,insist
onTorogenuineparts.
Checkbrakeoperationfrequently.Adjustandserviceas
required.
SoundPressure
Model74534TEhasasoundpressurelevelattheoperator’s
earof88dBA,whichincludesanUncertaintyValue(K)of
1dBA.
Model74536TEhasasoundpressurelevelattheoperator’s
earof86dBA,whichincludesanUncertaintyValue(K)of
1dBA.
Thesoundpressurelevelwasdeterminedaccordingtothe
proceduresoutlinedinENISO5395:2013.
SoundPower
Model74534TEhasaguaranteedsoundpowerlevelof100
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Model74536TEhasaguaranteedsoundpowerlevelof100
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Thesoundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinISO11094.
VibrationLevelforModel
74534TE
Hand-Arm
Measuredvibrationlevelforrighthand=0.8m/s
2
Measuredvibrationlevelforlefthand=0.6m/s
2
UncertaintyValue(K)=0.4m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.
WholeBody
Measuredvibrationlevel=0.79m/s
2
UncertaintyValue(K)=0.39m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.
VibrationLevelforModel
74536TE
Hand-Arm
Measuredvibrationlevelforrighthand=1.1m/s
2
Measuredvibrationlevelforlefthand=1.1m/s
2
UncertaintyValue(K)=0.6m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.
WholeBody
Measuredvibrationlevel=0.79m/s
2
UncertaintyValue(K)=0.39m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.