EasyManua.ls Logo

Toro 74978 - Operation; Adding Fuel

Toro 74978
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
Note:Determinetheleftandrightsidesofthemachine
fromthenormaloperatingposition.
AddingFuel
WhatisLPG?LPGstandsforliqueedpetroleumgasandis
morecommonlycalledpropane.LPGisaliquidfuelthatis
storedinatankunderpressure.Beforetheliquidleavesthe
tank,itisconvertedintoavapor.SinceLPGisstoredasboth
liquidandgas,itmayleakfromjointsorconnectionsthat
arenotsealedproperly.LPGbecomesammablewhenit
ismixedwithair.
TheLPGinformationinthisOperator'smanualisprovided
onlyasaguide.ConsulttheNFPA58:LiqueedPetroleum
GasCode,2008Editionforadditionalsafetyinformation.
ThisNationalFireProtectionAssociation(NFPA)code
pertainstothehandling,storing,transporting,andusageof
LPG.
Typeoffuel:HD5gradepropane
CAUTION
Undernocircumstancesshouldpropanetanks
lledbeyond80%capacitybeusedinservice.
Theuseofoverlledtanksmayresultintherelease
ofhighlyconcentratedandextremelyammable
liquidpropane.RefertotheSafetysection.
DANGER
LPGfuelisextremelyammableandvaporsare
explosive.
AreorexplosionfromLPGfuelcanburnyou,
others,andcausepropertydamage.
Neversmokearoundtank(s)andstayawayfrom
anopenameorwherefumesmaybeignited
byaspark.
Extinguishallsourcesofsparkoramewhen
approachingLPGtanksormowers.The
hazardincreasesforenclosedtrailersorstorage
locationswherevaporleakagemayoccurand
collect.
LPGisheavierthanairandmayaccumulatein
lowlyingareas,suchasditches,drains,orpits.
LPGtank(s)shouldbelledbytrainedand
qualiedpersonnelONLY.
Nevertamperwithorrepairthetank(s);contact
trainedandqualiedpersonnel.
DoNotchangethetank(s)whentheengineis
running.
Beforedisconnectingthehose(s),purgeallLPG
vaporsfromthesystem,byclosingthefuel
valve(s)onALLtanksandallowingtheengine
torununtilitstops.
Storethetank(s)awayfromheat,sparks,or
openames.
DoNotoperatewithoutentireexhaustsystem
inplaceandinproperworkingcondition.
DANGER
LPGvaporsandliquidescapingfromthetankmay
causeseriousinjuryordeath.Vaporsorliquidmay
causesuffocation,freezingoftissue,orfrostbite.
Storeandservicethemowerinawellventilated
area.
AnapprovedLPGdetectorinstalledintrailers
andstorageareasisrecommended.
LPGisheavierthanairandmayaccumulatein
lowlyingareas,suchasditches,drains,orpits.
Avoidbreathingofvapors.
Keepawayfromventvalve.
Keepawayfromeyesandskin.
Contacttrainedandqualiedpersonneliftank
showssignsoffrostedareas,makesahissing
sound,oremitsafoulodor.
Obtainimmediatemedicalattentionifcontact
occurswithvaporsorliquid.
15

Table of Contents

Related product manuals