Groundsmaster 3505--DHydraulic System Page 4 -- 70
Hydraulic Manifold Service
1. Manifold body
2. NWD #4 plug
3. Logic cartridge valve (LC1)
4. Nut
5. Solenoid coil
6. Solenoid cartridge valve (R1)
7. Braking cartridge valve (BV)
Figure 44
FRONT
RIGHT
1
4
25 ft--lb
(34 N--m)
60 in--lb
(6.8 N--m)
6
2
7
3
5
35 ft--lb
(47 N--m)
45 to 50 ft--lb
(61to68N--m)
120 in--lb
(13.6 N--m)
NOTE: The ports on the manifold are marked for easy
identification of components. Examples: BV is the deck
circuit braking valve and P1 is the gear pump connection
port (see Hydraulic Schematic to identify the function of
the hydraulic lines and cartridge valves at each port
location).
NOTE: The Groundsmaster 3505--D hydraulic man-
ifold uses several zero leak plugs. These plugs have a
tapered sealing surface on the plug head that is de-
signed to resist vibration induced plug loosening. The
zero leak plugs also have an o--ring as a s econdary seal.
If zero leak plug removal is necessary, lightly rap the
plug head using a punch and hammer before using an
allen wrench to r emove the plug: the impact will allow
plug removal with less chance of damage to the socket
head of the plug.