Problem
PossibleCauseCorrectiveAction
1.Thereisaliftcylindersealfailure.
1.Replacetheseals.
2.Thepressurereliefvalveisjammed
openorwronglyset.
2.Havethereliefvalvepressurechecked.
Consultyourauthorizeddistributor.
3.Thereisamalfunctioningcontrolvalve.3.Overhaulthecontrolvalve.
Acuttingunitfailstoliftoutofwork.
4.Thereismechanicalblockage.4.Removetheblockage.
1.Thehoseroutingortheorientationof
thehydraulicttingsisincorrect.
1.Movethecuttingunitsthroughoutthe
extremesofmovementandobserve
anytightnessinthehoses.Correctly
routethehosesandorientatethe
ttingsasnecessary.
2.Thepivotpointsaretootight.2.Releaseandgreasethepivotpointas
necessary.
3.Thecuttingunitoperatinginthe‘hold’
position.
3.Movethepositioncontrolswitchto
‘down/oat’position.
Thecuttingunitsdonotfollowthecontours
oftheground.
4.Theweighttransferissettoohigh.4.Reducetheweighttransfer.
1.Theseatsensorswitchis
malfunctioning.
1.Checkthemechanicalandelectrical
operationoftheswitch.
2.Thehydraulic-uidlevelislow.2.Fillthehydraulic-uidreservoirtothe
correctlevel.
3.Adriveshaftissheared.3.Checkthemotorandreeldriveshafts
andreplacethemifnecessary.
4.Thepressurereliefvalveisjammed
openorwronglyset.
4.Havethereliefvalvepressurechecked.
Consultyourauthorizeddealer.
5.Acuttingunitisjammed.
5.Clearanyjamsasnecessary.
6.Areelistightonthebedknife.
6.Adjustthesetting.
7.Acuttingunitcontrolvalveisinthe
‘off’position,causedbymalfunctioning
controlvalve.
7.Overhaulthecontrolvalve.
8.Acuttingunitcontrolvalveisinthe‘off’
position,causedbyanelectricalfault.
8.Havetheelectricalsystemcheckedfor
anelectricalfault.
Thecuttingunitsfailtostartupwhen
loweredintowork.
9.Theliftarmproximityswitchis
incorrectlyset.
9.Checkandadjusttheproximityswitch.
1.Thehosesareconnectedwrongly.
1.Checkthehydrauliccircuitandconnect
thehosescorrectly.
Thereelsrotateinthewrongdirection.
2.Thecuttingunitdriveswitchis
connectedwrongly.
2.Checktheelectricalconnectionsofthe
switch.
62