Figure36
1.Jamnut2.Turnbuckle
CheckingandAdjustingthe
Auger/ImpellerCable
ServiceInterval:Aftertherst2hours—Inspectthe
auger/impellercableandadjustitif
necessary.
Yearly—Inspecttheauger/impeller
cableandadjustorreplaceitif
necessary.
1.Removethe2screwsfromtherightsideofthebelt
coverasshown.
2.Liftuptherightsideofthebeltcover(Figure37).
Figure37
3.Withtheauger/impellerleverdisengaged,ensure
thatthegapbetweentheaugerclutchassemblyand
thetabis1/16inch(1.5mm)(Figure38).
Figure38
1.Tab
2.1/16inch(1.5mm)
4.Iftheauger/impellercableisnotproperlyadjusted,
dothefollowingsteps:
5.Loosenthejamnut(Figure39).
Figure39
1.Jamnut2.Turnbuckle
6.Loosenortightentheturnbucklethatadjuststhe
tensiononthecable(Figure39).
7.Adjusttheturnbuckleuntilyouobtaintheproper
gap.
8.Tightenthejamnut.
9.Insertthe2screwsyoupreviouslyremovedonthe
beltcover.
10.Iftheauger/impellercableisproperlyadjustedbut
aproblemremains,contactanAuthorizedService
Dealer.
19