Reelmaster 3550−D/3555−D/3575−D Page 5 − 17 Electrical System
Cutting Unit Operating Problems
Problem Possible Causes
Cutting units run (but should not) when raised. The mow control manifold proportional relief valve
(PRV) solenoid coil or circuit wiring is faulty.
A hydraulic problem exists (see Chapter 5 − Hydraulic
System in this manual).
Turn around switch or circuit wiring is faulty.
(RM 3555−D/3575−D).
The TEC Controller is faulty.
Cutting units do not run when lowered with the
mow/transport switch in the MOW position.
Fuse(s) is (are) faulty (other electrical components
most likely affected as well).
Engine temperature is high (above 220°F (105°C) or
engine temperature sender or circuit wiring is faulty.
The transport/mow switch is out of adjustment or the
transport/mow switch or circuit wiring is faulty.
The turn around switch is out of adjustment or the turn
around switch or circuit wiring is faulty
(RM 3555−D/3575−D).
The mow control manifold proportional relief valve
(PRV) solenoid coil or circuit wiring is faulty.
A hydraulic problem exists (see Chapter 5 − Hydraulic
System in this manual).
The TEC Controller is faulty.
Cutting units will not raise. Fuse(s) is (are) faulty (other electrical components
most likely affected as well).
Raise switch in joystick assembly is faulty or raise
switch circuit wiring is faulty.
Lift control manifold solenoid valve coil(s) (S1, S3
and/or S4) or circuit wiring is faulty.
A hydraulic problem exists (see Chapter 5 − Hydraulic
System in this manual).
The TEC Controller is faulty.
Cutting units will not lower. Fuse(s) is (are) faulty (other electrical components
most likely affected as well).
Lower switch in joystick assembly is faulty or lower
switch circuit wiring is faulty.
Lift control manifold solenoid valve coil(s) (S1, S2, S3
and/or S4) or circuit wiring is faulty.
A hydraulic problem exists (see Chapter 5 − Hydraulic
System in this manual).
The TEC Controller is faulty.
Electrical
System

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toro Reelmaster 3575-D and is the answer not in the manual?

Toro Reelmaster 3575-D Specifications

General IconGeneral
BrandToro
ModelReelmaster 3575-D
CategoryLawn Mower
LanguageEnglish

Related product manuals