December 2002 TOSHIBA TEC 10 - 9 e-STUDIO160/200/250 DRIVE SYSTEM
034
Fig. 10-3-9
Connector
Screw
PU guide assembly
Harness
Screw
Plate
11. Remove paper guide B and side cover as-
sembly. (See Fig. 2-6-15 and 2-6-16)
12. Remove PC I/F PWA. (See Fig. 2-6-28)
13. Remove high voltage power supply.
(See Fig. 2-6-29 and 2-6-30)
14. Remove main drive gear assembly.
(See Fig. 10-3-1 to 10-3-4)
15. Detach the harness and remove PU contact.
Note: If contact is found dirty, clean with a cotton
swab.
16. Detach the relay connector and remove 7
screws.
17. Pull out the PU contact harness through the hole
Fig. 10-3-11, release 2 tabs, and remove PU
guide assembly.
034-1
Fig. 10-3-10
Connector
Bushing plate
Screw
[D] Registration roller
1. Open ADU (MD-0101) if it is attached.
2. Detach the toner cartridge and the process unit.
3. Detach upper right cover R. (See Fig. 2-6-14)
4. Loosen one screw, remove bushing plate and
detach the relay connector.
5. Detach 2 stop rings, slide bushing in the direc-
tion of the arrow, and remove registration roller
assembly.
Fig. 10-3-11
035
Registration roller
assembly
Stop ring

Table of Contents