DEVELOPMENT SYSTEM
12 - 9
12.5 Disassembly and Replacement
[A] Process unit
Note:
Make sure to perform “05-280” and take off the process unit before the developer material is
replaced.
(1) Open the bypass tray, ADU and transfer
cover.
(2) Open the front cover and take off the toner
cartridge.
(3) Disconnect 1 connector. Loosen 2 screws
and pull out the process unit.
Note:
When installing the process unit, make sure
that the connector (harness) is not caught
under the developer unit.