June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 55
3
(7) Tighten the positioning pin at the front side.
Close the RADF to fit the positioning pin into
the hole at the front side of the RADF. (For
the front side, adjust the RADF position all
around.)
Fig.3-56
(8) While peering inside from the left side, close
the RADF. Check the positions of the holes
of the RADF and pins and then fit their posi-
tions by moving the RADF back and forth.
(For the front side, also adjust the RADF
position right and left.) Make sure not to dis-
locate the positions of the pin and hole at the
rear side.
Fig.3-57
(9) Open the RADF to tighten 2 hand screws.
Close the RADF and then check again that
the positioning pins fit smoothly into the
holes on the RADF.