June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 77
3
[B] Adjustment
Simplex copying:
(1) Shift the aligning plate with the scale as the guide shown in the figure below to adjust the skew.
Fig.3-96
(2) If the image skew is "C" as shown in the figure below, shift the aligning plate in the direction of
"+", and if "D", shift it to "-".
Fig.3-97
Fig.3-98
Shift the aligning plate in the direction of "+". Shift the aligning plate in the direction of "-".
C
D
05/11