230 ACE-tronics G9 ASD Installation and Operation Manual
Traverse Jump Step (Not Used With the ACE-tronics G9
ASD)
Program Special Traverse
This parameter setting is used in the setup of the Traverse control mode of
operation. This setting is used as a multiplier to establish the amount that the
frequency is increased or decreased while using the Traverse function when a
short burst of rapid speed change is required.
See the Traverse Control Instruction Manual (P/N E6581337) for additional
information on this feature.
Direct Access Number F984
Parameter Type — Numerical
Factory Default 10.0
Changeable During RunNo
Minimum — 0.0
Maximum — 50.0
Units — %
Motion Control
Program Crane/Hoist Motion Control
This parameter sets the axis of motion to be controlled by the ASD.
Settings:
Closed Loop Hoist
Open Loop Hoist (Used During Emergency Lift ONLY)
Main Hoist
Bridge
Rotate
Direct Access Number F985
Parameter Type — Selection List
Factory Default Closed Loop Hoist
Changeable During RunNo
F984 F985