108 H7 ASD Operation Manual
Preset Speed #12
Program
Pattern Run Control
Preset Speeds
12
This parameter assigns an output frequency to binary number 1100 and is
identified as Preset Speed #12. The binary number is applied to S1S4 of the
Control Terminal Strip to output the Preset Speed (see F018 for further
information on this parameter).
Direct Access Number F291
Parameter TypeNumerical
Factory Default0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed #13
Program
Pattern Run Control
Preset Speeds
13
This parameter assigns an output frequency to binary number 1101 and is
identified as Preset Speed #13. The binary number is applied to S1S4 of the
Control Terminal Strip to output the Preset Speed (see F018 for further
information on this parameter).
Direct Access Number F292
Parameter TypeNumerical
Factory Default0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed #14
Program
Pattern Run Control
Preset Speeds
14
This parameter assigns an output frequency to binary number 1110 and is
identified as Preset Speed #14. The binary number is applied to S1S4 of the
Control Terminal Strip to output the Preset Speed (see F018 for further
information on this parameter).
Direct Access Number F293
Parameter TypeNumerical
Factory Default0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed #15
Program
Pattern Run Control
Preset Speeds
15
This parameter assigns an output frequency to binary number 1111 and is
identified as Preset Speed #15. The binary number is applied to S1S4 of the
Control Terminal Strip to output the Preset Speed (see F018 for further
information on this parameter).
Direct Access Number F294
Parameter TypeNumerical
Factory Default0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
F291 F294