H7 ASD Operation Manual 65
Input #12 Terminal Assignment
Program
Terminal Selection Parameters
Input Terminal
Assignment
S12
This parameter selects the functionality of the #12 input terminal.
Note: The S12 input terminal may be used without the ASD-Multicom option
board.
Without the ASD-Multicom option board the S12 terminal assignment
information will be stored in volatile memory. The terminal assignment
information will be lost if the system is powered down or reset.
In addition, the input terminal must be specified as Normally Open or
Normally Closed.
This parameter sets the programmable terminal #12 to 1 of the 68 possible
functions that are listed in Table 6 on pg. 67.
Direct Access Number F122
Parameter TypeSelection List
Factory DefaultUnassigned
Changeable During Run — No
Input #13 Terminal Assignment
Program
Terminal Selection Parameters
Input Terminal
Assignment
S13
This parameter selects the functionality of the #13 input terminal.
Note: The S13 input terminal may be used without the ASD-Multicom option
board.
Without the ASD-Multicom option board the S13 terminal assignment
information will be stored in volatile memory. The terminal assignment
information will be lost if the system is powered down or reset.
In addition, the input terminal must be specified as Normally Open or
Normally Closed.
This parameter sets the programmable terminal #13 to 1 of the 68 possible
functions that are listed in Table 6 on pg. 67.
Direct Access Number F123
Parameter TypeSelection List
Factory DefaultUnassigned
Changeable During Run — No
Input #14 Terminal Assignment
Program
Terminal Selection Parameters
Input Terminal
Assignment
S14
This parameter selects the functionality of the #14 input terminal.
Note: The S14 input terminal may be used without the ASD-Multicom option
board.
Without the ASD-Multicom option board the S14 terminal assignment
information will be stored in volatile memory. The terminal assignment
information will be lost if the system is powered down or reset.
In addition, the input terminal must be specified as Normally Open or
Normally Closed.
This parameter sets the programmable terminal #14 to 1 of the 68 possible
functions that are listed in Table 6 on pg. 67.
Direct Access Number F124
Parameter TypeSelection List
Factory DefaultUnassigned
Changeable During Run — No
F122 F124