H9 ASD Installation and Operation Manual 249
E-25
Stop Positioning
Retention Error
Load movement while stopped.
F381 setting is too low.
Encoder malfunction.
Creep speed is too high.
E-26 CPU2 Fault CPU malfunction.
Control board malfunction.
E-50/E-51 Sink/Source Setting
Error
Improperly positioned Sink/Source jumper on the Terminal board or on an
option device (see J100 at the Terminal PCB of the ASD).
Sink/Source configuration is incorrect.
EEP1 EEPROM Fault EEPROM write malfunction.
Make a service call.
EEP2/EEP3 EEPROM Read Error EEPROM read malfunction.
Make a service call.
EF1/EF2 (Earth) Ground Fault Ground fault at the motor.
Ground fault at the output of the ASD.
Current leakage to Earth Ground.
EPHI Input Phase Failure 3-phase input to the ASD is low or missing at the R, S, or T input terminals.
EPHO Output Phase Failure 3-phase output from the ASD is low or missing at the U, V, or W output
terminals or at the input to the motor.
ERR2 RAM Fault Internal RAM malfunction.
Make a service call.
ERR3 ROM Fault Internal ROM malfunction.
Make a service call.
ERR4 CPU Fault CPU malfunction.
Control board malfunction.
Make a service call.
ERR5 Communication Error Communication time out error.
Communication malfunction.
Improper or loose connection.
Improper system settings.
ERR6
Gate Array Fault Main Gate Array is defective.
ERR7 Low -Current Improper Low- Current detection level settings at F609F612.
ERR8
Option Device Fault Check installation, connections, and option device manual.
ERR9 Flash Memory Fault Flash memory malfunction.
Make a service call.
LED Screen LCD Screen Possible Causes