5
Installation example of water circuit:-
(1) (2)
(3) (4)
(5) (6)
The water circuit for a system without a buffer tank [ (1) , (2) , (3) , (5) ] requires 17.5l/min
(804XWH = 13.0l/min) or more. This water flowing requires 5 or more branches of Floor heating or
Radiators etc.
Less than 5 branches may cause a flow deficiency. In this case, please provide a buffer tank and
secondary pumps, as shown in (4).