42 HX7+ ASD Quick Start Guide
4. Adjust Accel/Decel Automatically?
When enabled, the HX7+ ASD adjusts the 
acceleration and deceleration rates according to the 
applied load. The acceleration and deceleration 
times range from 12.5 to 800% of the programmed 
values [e.g., Acceleration Time 1 (F009) and 
Deceleration Time 1 (F010) adjusted for the actual 
Accel/Decel times used].
Settings:
0 — Disabled
1 — Enabled
The motor and the load must be connected prior to selecting Automatic Accel/Decel.
If Automatic Accel/Decel is not enabled, the Acceleration screen will appear followed by the 
Deceleration screen as shown below.
5. Volts Per Hertz Setting
This function establishes the relationship between 
the output voltage and the output frequency of the 
ASD.
Settings:
0 — Constant Torque
1 — Variable Torque
2 — Automatic Torque Boost
3 — Sensorless Vector Control (speed)
4 — Automatic Torque Boost with Automatic Energy Saving
5 — Sensorless Vector Control (speed) with Automatic Energy Saving
6 — V/f 5-Point Setting (opens 5-point setting screen)
7 — Sensorless Vector Control (speed/torque switching)
8 — PG Feedback Vector Control (speed/torque switching)
9 — PG Feedback Vector Control (speed/position switching)
6. Motor Current Rating
This parameter allows the user to input the full-load 
amperage (FLA) of the motor. This value is used by 
the HX7+ ASD to determine the motor overload 
protection setting for the motor. The value is found 
on the nameplate of the motor.
Deceleration Time
Acceleration Time
Accelerati
on Time
Decelerati
on Time