4.24 FL inverter/LCD unit 4 Replacement Procedures
4.24 FL inverter/LCD unit
Removing the FL inverter/LCD unit
To remove the FL inverter/LCD unit, follow the steps below and refer to Figure 4-31 and 4-
32.
1. Remove the following screw fixing the FL inverter.
M2×3C S-FLAT HEAD screw x1
2. Peel the insulator and disconnect the two cables from the both sides of the connector
on the FL inverter.
3. Remove the FL inverter.
M2×3C S-FLAT HEAD
FL inverter
Insulator
Figure 4-31 Removing the FL inverter
PORTEGE R200 Maintenance Manual (960-519) [CONFIDENTIAL] 4-45