FILE NO. SVM-02007
– 37 –
Shield pipe
Air filter
Hook
Hook
(Attach to the front panel)
2
Wireless remote
control
65 mm or more
170 mm
or more
170 mm
or more
1
Installation
plate
6
Purifying filter
5
Zeolite filter
4
Remote control holder
Insulate the refrigerant
pipes separately with insulation,
not together.
For the rear left and left piping
Wall
Insert the cushion between
the indoor unit and wall,
and tilt the indoor unit for better
operation.
9-1-1. Installation Diagram of Indoor and Outdoor Units
6 mm thick heat resisting
polyethylene foam
Before installing the wireless
remote control
• With the remote control cover
open, load the batteries supplied
correctly, observing their
polarity.
2 Wireless remote control
3 Batteries
Cover
As shown in the figure, hang power cord
and connecting cable downward, and
take out it along piping connection port.
The auxiliary piping can be
connected the left, rear left,
rear right, right, bottom right or
bottom left.
Left
Rear left
Right
Rear right
Bottom right
Bottom left
Do not allow the drain hose to
get slack.
Cut the piping hole
sloped slightly
Make sure to run the drain hose
sloped downward.
Fig. 9-1-1
8
Flat head wood screw
Saddle
Extension
drain hose
(Option:
RB–821SW)
100 mm or
more from wall
600 mm or more
50 mm or more
from wall
250 mm
or
more from
wall
200 mm or more