FILE NO. SVM-02007
– 3 –
Unit model Indoor RAS-10UKV-E
Outdoor RAS-10UAV-E
Current limited —
Cooling capacity (kW) 2.5
Cooling capacity range (kW) 0.9 – 3.0
Heating capacity (kW) 3.2
Heating capacity range (kW) 0.7 – 4.0
Power supply 220 – 240V –1Ph –50/60Hz
Electric Indoor Operation mode Cooling Heating
characteristics Running current (A) 0.15 0.15
Power consumption (W) 30 30
Power factor (%) 87 87
Outdoor Operation mode Cooling Heating
Running current (A) 3.42 3.69
Power consumption (W) 750 810
Power factor (%) 95 95
Starting current (A) 3.84
COP (Cooling / Heating) 3.21
Operation noise Indoor High (Cooling / Heating) (dB•A) 38/39
Low (Cooling / Heating) (dB•A) 27/29
Outdoor (Cooling / Heating) (dB•A) 46/47
Indoor unit Unit model RAS-10UKV-E
Dimension Height (mm) 275
Width (mm) 790
Depth (mm) 208
Net weight (kg) 10
Fan motor output (W) 30
Air flow rate (Cooling / Heating) (m
3
/h) 530/590
Outdoor unit Unit model RAS-10UAV-E
Dimension Height (mm) 530
Width (mm) 660
Depth (mm) 240
Net weight (kg) 28
Compressor Motor output (W) 750
Type Single rotary type with DC-inverter variable speed control
Model DA89X1F-20D
Fan motor output (W) 18
Air flow rate (Cooling / Heating) (m
3
/h) 1300/1300
Piping connection Type Flare connection
Indoor unit Liquid side ∅6.35
Gas side ∅9.52
Outdoor unit Liquid side ∅6.35
Gas side ∅9.52
Maximum length (Per unit) (m) 10
Maximum chargeless length (m) 10
Maximum height difference (m) 8
Refrigerant Name of refrigerant R-410A
Weight (kg) 0.64
Wiring connection Power supply 3 Wires: includes earth
Interconnection 4 Wires: includes earth
Usable temperature range Indoor (Cooling / Heating) (°C) 21 – 32 / 0 – 28
Outdoor (Cooling / Heating) (°C) 10 – 43 / –10 – 24
Accessory Indoor unit Installation plate 1
Wireless remote control 1
Remote controller holder 1
Flat head wood screw 2 (∅3.1 x 16L)
Purifying filter 1
Zeolite filter 1
Batteries 2
Mounting screw 6 (∅4 x 25L)
Installation manual 1
Owner’s manual 1
Outdoor unit Drain nipple 1
1. SPECIFICATIONS
1-1. Specifications
• The specification may be subject to change without nitice for purpose of improvement.