18
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1 Reactor L = 10mH, 16A
2 Outdoor fan motor DC140V, 43W
3 Suction temp. sensor (TS sensor)
10k
(25°C)
4 Discharge temp. sensor (TD sensor)
62k
(20°C)
5 Outside air temp. sensor (TO sensor)
10k
(25°C)
6 Heat exchanger temp. sensor (TE sensor)
10k
(25°C)
7 Terminal block (5P) 20A, AC250V
9 COIL FOR P.M.V. DC12V
10 Coil for 4-way valve AC220-240V
CAM-MD12TCTH-5
STF-H01AJ1872A1
Compressor 3-phases 4-poles 750W
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA111A1F-20F1
Parts name Model name Rating
CH-57-FC
ICF-140-43-4R
No.
Fan motor (for indoor)
2 Room temp. sensor (TA-sensor)
10k
at 25°C
3 Heat exchanger temp. sensor (TC-sensor)
10k at 25°C
4
Louver motor
Output (Rated) 1W, 16 poles, DC12V
( - )
(
-
)
MSBPC20F04
MF-340-30-3 DC250~370, 30W
Parts name
1
Specif icationsType
5
Heat exchanger temp. sensor (Tcj-sensor)
10k at 25°C
(
-
)
JX0-5B
FILE NO. SVM-12051