54
10-3. Indoor Unit
10-3-1. Installation Place
10-3-2. Cutting a Hole and Mounting
Installation Plate
Cutting a hole
When installing the refrigerant pipes from the rear.
1. After determining the pipe hole position on the
installation plate (
ð
) drill the pipe hole (Ø65
mm) at a slight downward slant to the outdoor
side.
NOTE :
When drilling into a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
Mounting the installation plate
Fig. 10-3-3
Pipe hole
62
85
82.5
170
Indoor unit
Thread
Hook
Weight
Pipe hole
Mounting screw
Hook
Hook
Installation
plate
Anchor bolt holes
2 m or more from floor
7
1
65 mm
100 mm
Pipe
hole
Fig. 10-3-2
FILE NO. SVM-12051
A place which provides the spaces around the
indoor unit as shown in the above diagram.
A place where there is no obstacle near the air inlet
and outlet.
A place that allows easy installation of the piping to
the outdoor unit.
A place which allows the front panel to be opened.
The indoor unit shall be installed as top of the
indoor unit comes to at least 2 m height.
Also, it must be avoided to put anything on the top
of the indoor unit.
CAUTION
Direct sunlight to the indoor unit’s wireless
receiver should be avoided.
The microprocessor in the indoor unit should not
be too close to RF noise sources.
(For details, see the owner’s manual.)
<Remote control>
A place where there are no obstacles such as a
curtain that may block the signal from the indoor
unit.
Do not install the remote control in a place exposed
to direct sunlight or close to a heating source, such
as a stove.
Keep the remote control at least 1 m apart from the
nearest TV set or stereo equipment. (This is
necessary to prevent image disturbances or noise
interference.)
The location of the remote control should be
determined as shown below.
Fig. 10-3-1
(Top view)
Indoor unit
Reception
rang
e
Reception
rang
e
Remote
contr
ol
Remote
contr
ol
(Side vie
w)
Indoor unit
45
°
4
5
°
75
°
The center of the pipe hole
is above the arrow