Item
Operation flow and applicable data,etc
Description
.
22. POWER
Mode
Selection
([POWER-SEL] button on the remote controller
is pressed)
The function is used when its circuit breaker is
shared with other electrical appliances.
It limits the maximum current/ power
consumption to 100%, 75% or 50%.
The lower the percentage, the higher the saving
and also the longer the compressor lifetime.
When the level is selected, Power-SEL
level flashes on LCD display for 3
seconds. In case of 75% and 50%
level, number "75" or "50" also flashes
for 2 seconds.
Note :
Due to the reason that POWER
SELECT FUNCTION limits the
maximum current, inadequate
capacity may occur.
Power Selection 50% is 50% of rate maximum
Power Selection 75% is 75% of maximum
current.
current.