5
CAUTION
  NOTE
If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall.
After passing the connecting pipe through the pipe hole, connect the 
connecting pipes to the auxiliary pipes and wrap the facing tape around 
them.
• Bind the auxiliary pipes (two) and connecting cable with facing tape 
tightly. In case of leftward piping and rear-leftward piping, bind the 
auxiliary pipes (two) only with facing tape.
 
•  Carefully arrange pipes so that any pipe does not stick out of the rear 
plate of the indoor unit.
•  Carefully connect the auxiliary pipes and connecting pipes to one an-
other and cut off the insulating tape wound on the connecting pipe to 
avoid double-taping at the joint; moreover, seal the joint with the vinyl 
tape, etc.
•  Since dewing results in a machine trouble, make sure to insulate both 
connecting pipes. (Use polyethylene foam as insulating material.)
•  When bending a pipe, carefully do it, not to crush it. 
Indoor Unit Fixing
• For detaching the indoor unit from the 
installation plate, pull the indoor unit toward 
you while pushing its bottom up at the 
specifi ed parts.
1
2
1.  Pass the pipe through the hole in the wall and hook the indoor unit on the 
installation plate at the upper hook.
2.  Swing the indoor unit to right and left to confi rm that it is fi rmly hooked up on 
the installation plate.
3.  While pressing the indoor unit onto the wall, hook it at the lower part on the 
installation plate. Pull the indoor unit toward you to confi rm that it is fi rmly 
hooked up on the installation plate.
Drainage
1.  Run the drain hose sloped downwards.
2. Put water in the drain pan and make sure that the water is drained out of 
doors.
3. When connecting extension drain hose, insulate the connecting part of 
extension drain hose with shield pipe.
 NOTE
•  The hole should be made at a slight downward slant on the outdoor side.
Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew-dropping.
This air conditioner has the structure designed 
to drain water collected from dew, which forms 
on the back of the indoor unit, to the drain pan. 
Therefore, do not store the power cord and other 
parts at a height above the drain guide.
CAUTION
Auxiliary pipes
Installation plate
Indoor unit
Connecting cable
Hook here.
Hook
1 Installation plate
Press
(unhook)
Push Push
Do not rise the
drain hose.
Do not form the
drain hose into
a wavy shape.
50 mm
or more
Do not put the
drain hose end
into water.
Do not put the
drain hose end
in the drainage ditch.
Extension drain hose
Inside the room
Shield pipe
Drain hose
Space for pipes
Drain
guide
Wall
1110251159.indb   51110251159.indb   5 12/21/07   11:52:46 AM12/21/07   11:52:46 AM