5. SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Indoor Unit
RAS-M10YKV-E, RAS-M13YKV-E, RAS-M16YKV-E
RAS-M10YKCV-E, RAS-M13YKCV-E, RAS-M16YKCV-E
No. Parts name Type Specifications
1 Fan motor (for indoor) TICF-35-19-4 DC 35V, 19W
2 Thermo. sensor (TA-sensor) ( ) 10k at 25°C
3 DC-DC transformer (T01) SWT-34 DC 390V, Secondary DC 35V, 12V, 7V
4 Microcomputer TMP87CM40AF
5
Heat exchanger sensor
( ) 10k at 25°C
(TC-sensor)
6 Line filter (L01) UF-253Y0R7 25mH, AC 0.7A
7 Diode (DB01) RBV-406 or D3SBA60 4A, 600V
8 Capacitor (C02) KMH450VNSN100M25B 100µF, 450V
9 Fuse (F01) TSCR6.3A T6.3A, 250V
10 Power supply IC (IC01) MA2830P-FJ 8A, 850V
11 Varistor (R21, R109) 15G561K 560V
12 Resistor (R01) ERF-5TK5R6 5.6, 5W
13 Louver motor MP35EA7 Output (Rated) 2W, 10 poles, 1 phase DC12V