– 52 –
Table 8-1-2
NOTE :
UL : Ultra Low, SUL : Super Ultra Low
Operation
mode
COOL
DRY
HEAT
FAN
mode
H
M+
M
L
L–
UL
SUL
L–
SUL
H
M+
M
L
L–
UL
SUL
M10
Motor speed Air flow rate
(rpm) (m³/h)
1100 470
1100 470
1010 440
910 380
810 320
770 300
760 300
810 320
760 300
1200 520
1200 520
1100 470
930 390
930 390
810 320
670 260
M13
Motor speed Air flow rate
(rpm) (m³/h)
1200 520
1140 510
1050 470
910 380
820 330
770 300
760 300
820 330
760 300
1280 560
1280 560
1100 470
930 390
930 390
820 330
730 290
M16
Motor speed Air flow rate
(rpm) (m³/h)
1350 600
1300 580
1190 520
980 420
920 380
870 360
820 330
920 380
820 330
1350 600
1350 600
1200 520
980 420
980 420
920 380
730 290
8-1-6. Louver Control
(1) Vertical air flow louvers
Positions of vertical air flow louvers are automati-
cally controlled according to the operation status
(AUTO, COOL, DRY, HEAT). Besides, positions of
vertical air flow louvers can be arbitrarily set by
pressing the [SET] button. The louver position which
has been set by the [SET] button is stored in micro-
computer, and the louver is automatically set at the
stored position in the next operation.
(2) Swing
If the [AUTO] button is pressed during running
operation, vertical air flow louvers start swinging.
When the [AUTO] button is pressed again, swinging
stops.
8-1-7. Indoor Fan Control (DC Fan Motor)
The indoor fan is operated by motor speed non-step
variable DC drive system motor. For flow rate, motor
speed is controlled manually in three steps (LOW,
MED, HIGH), and with the unit of 10 rpm from upper
limit to lower limit in AUTO mode as described in
Table 8-1-2. It is not selected by relay, so selecting
sound does not generate.
8-1-4. Prevent-Freezing Control
The indoor heat exchanger sensor detects refriger-
ant vapor temperature in COOL/DRY operation. If
the temperature is below the specified value, com-
pressor motor speed is reduced so that operation is
performed in temperature below the specified value
to prevent-freezing of indoor heat exchanger.
8-1-5. P. M. V. (Pulse Modulating Valve)
Using P.M.V., refrigerant flow of refrigeration cycle is
varied for the optimum temperature. Controlling
each unit separately by four P.M.V. corresponds to
difference of pipe length, fan speed, and unit tem-
perature.
If an error occurs on cycle temperature when power
source of the air conditioner has been turned on,
and if start/stop times of the outdoor unit are 30
times, move the valve once until it hits on the stopper
for positioning of the valve. In this case, ticktack
sound may be heard.