– 26 –
Item
2. Indoor fan
motor control
Operation flow and applicable data, etc.
<In cooling operation>
(This operation controls the fan speed at indoor unit side.)
The indoor fan (Turbo fan) is operated by DC motor.
The fan rotates in 5 stages in MANUAL mode, and in 5 stages
in AUTO mode, respectively. (Table 1)
Description
* Symbols
UH : Ultra High
H : High
M+ : Medium+
M : Medium
L+ : Low+
L : Low
L- : Low–
UL : Ultra Low
SUL : Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
(Fig. 1)
(Fig. 2)
(Table 1) Indoor fan air flow rate (Cool/Dry/Fan only)
(Table 2) Indoor fan air flow rate (Heat)
Fan speed
level
WF
WE
WD
WC
WB
WA
W9
W8
W7
W6
W5
W4
W3
W2
W1
COOL
FAN
ONLY
UH
H
M+
M
L+
L
L–
UL
SL
DRY
L–
UL
SL
RAS-M10SMUV-E
RAS-M10SMUCV-E
Fan speed Air flow rate
(rpm) (m
3
/h)
650 590
650 590
650 590
630 570
600 540
570 500
550 480
530 460
500 430
480 410
450 380
370 290
350 270
350 270
350 270
RAS-M13SMUV-E
RAS-M13SMUCV-E
Fan speed Air flow rate
(rpm) (m
3
/h)
680 620
680 620
680 620
630 570
600 540
590 530
550 480
530 460
500 430
480 410
450 380
370 290
350 270
350 270
350 270
RAS-M16SMUV-E
RAS-M16SMUCV-E
Fan speed Air flow rate
(rpm) (m
3
/h)
720 660
720 660
720 660
680 620
650 590
630 570
600 540
550 480
520 450
500 430
450 380
370 290
350 270
350 270
350 270
Fan speed
level
WF
WE
WD
WC
WB
WA
W9
W8
W7
W6
W5
W4
W3
W2
W1
HEAT
UH
H
M+
M
L+
L
L–
UL
SL
RAS-M10SMUV-E
Fan speed Air flow rate
(rpm) (m
3
/h)
700 640
650 590
640 580
620 560
600 540
570 500
550 480
520 450
500 430
450 380
440 370
420 350
400 330
370 290
350 270
RAS-M13SMUV-E
Fan speed Air flow rate
(rpm) (m
3
/h)
730 670
680 620
640 580
620 560
600 540
590 530
560 490
530 460
500 430
450 380
440 370
420 350
400 330
370 290
350 270
RAS-M16SMUV-E
Fan speed Air flow rate
(rpm) (m
3
/h)
750 690
720 660
690 630
670 610
650 590
630 570
600 540
550 480
520 450
470 400
450 380
420 350
400 330
370 290
350 270
+2.5
Ta
[
˚C
]
+2.0
+1.5
+1.0
+0.5
Tsc
a
b
c
d
e
M+(WB)
*3
*4
*5
L(W6)
Air volume AUTO
L
L+
M
M+
H
W6
(L + M) / 2
W9
(M + H) / 2
WC
Indication Fan speed
Fan speed setup
COOL ON
AUTO
MANUAL
*3 :Fan speed = (M + –L) x 3/4 + L
*4 :Fan speed = (M + –L) x 2/4 + L
*5 :Fan speed = (M + –L) x 1/4 + L
(Linear approximation
from M+ and L)