9 TEST OPERATION
Check and Test operation
Be sure to test the piping connections for gas leak.
Check the flare nut connections, valve stem cap
connections and service port cap connections for
gas leak with a leak detector or soap water.
Test operation
To test the system, push and hold RESET button for
10 sec. (There will be one short beep.)
Service port
cap connection
Valve stem
cap connection
Flare nut
connections
(Outdoor unit)
Flare nut
connections
(Indoor unit)
10 INSTALLATION / SERVICING TOOLS
Tools
Tools
Gauge manifold
Charge hose
Electronic balance for
refrigerant charging
Torque wrench
(nominal diam. 1/2, 5/8)
Tools
Flare tool (clutch type)
Gauge for projection
adjustment
Vacuum pump adapter
Gas leakage detector
Applicable to R22 model
o
o
¡
o
¡
: Newly prepared (They are special requirements for R410A, separated from those for R22.)
o
: Existing tools are available.
For the details of the tools, refer to the Installation manual of the outdoor unit.
Applicable to R22 model
¡
__ ____
¡
o

Table of Contents