8-1-2. Forced Defrost Setup of Remote Controller (For wired remote controller only)
(Prepare in advance)
1
2
3
4
5
6
7
8
8-1-3. LED Display on P.C. Board
1. D501 (Red)
It goes on (Goes on by operation of the main microcomputer) at the same time when the power supply is
turned on.
It flashes with 1-second interval (every 0.5 second): When there is no EEPROM or writing-in operation fails.
It flashes with 10-seconds interval (every 5 second): During DISP mode
It flashes with 2-seconds interval (every 1 second): While setting of function select (EEPROM)
2. D403 (Red)
It goes on when power supply of the remote controller is turned on. (Lights on hardware)
3. D504 (Green): Sub bus communication
It flashes for 5 seconds in the first half of communication with the remote controller. (Group master unit)
It flashes with 0.2-second interval (for 0.1 second) for 5 second in the latter half of communication between
master and follower in the Gr indoor unit.
4. D14 (Orange)
It flashes while receiving the serial signal from the outdoor unit. (Hardware)
5. D15 (Green)
It flashes while sending the serial signal to the outdoor unit. (Hardware)
Push [MENU] and [] buttons simultaneously for at least 10 seconds.
In the air-conditioning group control mode, and the indoor unit No. are displayed. The indoor unit
number displayed first is the main indoor unit number.
In the non-group control mode (only one indoor unit), only 1-1 is displayed on the left.
Push [] or [] button to adjust the indoor unit number. The indoor unit number in the group
control will be changed cyclically. Select an indoor unit to change the settings and push
[TIME] button to confirm.
The fan of the selected indoor unit starts its operation and the swing operation starts after confirmation if it
has the louvers.
Using [] or [] button, set the CODE No. to [8C].
Use [MENU] button to adjust the flash from CODE No. to SET DATA on the left. Push [] or
[] button to set SET DATA to [0001].
Push [MENU] button to adjust the flash to CODE No. on the right after pushing [TIME] button to
confirm.
Push [ON/OFF] button to complete the setting when the setting is completed.
To change the settings of another indoor unit, repeat from step 1.
Push [ON/OFF] button to start the air conditioner
Select the HEAT mode
After a while, the forced defrost signal is sent to the outdoor unit and then the outdoor unit starts defrost
operation.
(The forced defrost operation is performed for Max. 12 minutes)
After defrost operation finished, the operation returns to the heating operation.
Note: to execute the defrost operation again, start procedure from step 1.
(If the forced defrost operation was executed once, setting of the above forced defrost operation is cleared.)