EasyManua.ls Logo

Toshiba Strata DK 16 - 4 Terminal and Modem Installation Guide

Toshiba Strata DK 16
321 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-4-
TABLE RM-A
PPTC MODIFIED WIRING FOR EXTERNAL MODEM TO TTY CONNECTION
FIGURE 4
REMOTE MAINTENANCE USING IMDU MODEM (DK16 ONLY)
REMOTE
MODEM
RS-232
CABLE
CO LINE
TELEPHONE
NETWORK
ROM
AND
RAM
DK16
CO LINE
CIRCUIT
DK16
CO line connects to IMDU port (619)
via: DISA, Ring transfer, or ringing
assignments in Program 78
PIOU OR PIOUS
CO LINE
IMDU
TIME
SWITCH
PPTC1A-5M ADAPTORQSMU OR PIOU/PIOUS,
TTY JACK
MODULAR PIN NO.
MODULAR PIN NO.
1
2
3
4
5
6
RD
TD
DSR
DTR
DCD
SG
RD,
TD,
DSR,
DTR,
DCD,
SG,
6
5
4
3
2
1
to
to
to
to
to
to
3*
2*
6
20*
8*
7
4 Jumper to 5
RD
TD
DSR
DTR
DCD
SG
RTS to CTS
to
to
to
to
to
to
DB25 PIN NO.
MODEM
RS-232
LEAD NAME
PPCT (Modular to DB25) ADAPTOR, MODIFIED WIRING FOR
CONNECTING TTY JACK TO AN EXTERNAL MODEM:
IMPORTANT:
*
PPTC1A-5M, pins 2 & 3 and pins 8 & 20 must
be reversed in the field, as shown, for modem
connection. Set Hayes modem to track status of
carrier detect signal (AT & C1) and to answer
(ATS0 = 1).

Table of Contents

Related product manuals