REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-33-
TABLE RM-AB
PROGRAM 34
HOLD RECALL TIMING
ACTIONSTEP DISPLAY/PRINTOUT
1 >MODE PROGEnter the Program Mode
At the >MODE prompt, enter P R O G CR.
2 P 34
P34
Enter Program Number 34
Press CR.
3 P34 05Refer to the record sheet and enter the required
port number.
Example: Port 05, enter 0 5.
4 Press #. The present data will be displayed.
P34 05# 032
5 Refer to the record sheet and enter the required timing.
Example: 160 seconds, enter 1 6 0.
6
P34 05# 032 160
P34 ##
P
To Exit Program/Store Data
A)
B)
C)
P
P34 05# 032 160
To store data, press CR.
Continue returning to step 3 until all Program 34
data has been entered.
To exit this program, press # # CR.
NOTE:
, use T
y
pe 2 procedure.Pro
g
ram 35
TABLE RM-AC
PROGRAM 36
FIXED CALL FORWARD
ACTIONSTEP DISPLAY/PRINTOUT
1 >MODE PROGEnter the Program Mode
At the >MODE prompt, enter P R O G CR.
2 P 36
P36
Enter Program Number 36
Press CR.
3
P36 00
Refer to the System Record Sheet and enter the
port number for the station that will have a Fixed
Call Forward button. Example: Port 00, enter 0 0.
4 Press #. The present data will be displayed.
P36 00# NN
5 Refer to the System Record Sheet and enter
the port to be forwarded to when the Fixed
Call Forward button is pressed. Example: Port 04, enter 0 4.
P
P36 00# NN 04
6
P36 00# NN 04
P36 ##
P
To Exit Program/Store Data
A)
B)
C)
To store data, press CR.
Continue returning to step 3 until all Program 36
data is entered.
To exit this program, press # # CR.