6
3. Ligh
tning & ESD Protection
P
roper grounding is extremely important for outdoor devices.
By using shielded CAT5e (or above) cable with ground wire for the
connection and the provided PoE adapter (method ), you can
e ectively eliminate ESD attacks. If you use the general CAT5e cable for
the connection, then it is necessary to connect the grounding terminal
of the CPE to earth ground through grounding cable (method ).
2
1
Shielded CAT5e (or above)
Cable with Ground Wire
Grounding Terminal and Cable
Grounded 3-wire
Power Outlet
CPE
Shielded CAT5e (or above)
Cable with Ground Wire
PoE Adapter
with Earth
Ground
Grounding
Terminal
Grounding
Cable
Earth Ground
T
wo Methods:
2
2
1
1
1
1

Other manuals for TP-Link CPE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TP-Link CPE Series and is the answer not in the manual?

TP-Link CPE Series Specifications

General IconGeneral
ModelCPE Series
Wireless StandardsIEEE 802.11a/n
Frequency5 GHz
AntennaDirectional
Wireless SecurityWPA/WPA2, WPA-PSK/WPA2-PSK
Operating ModesAccess Point, Client, Repeater, Bridge
Power SupplyPassive PoE (Power over Ethernet)
Operating Temperature-30°C to 70°C
Storage Temperature-40°C~70°C (-40℉~158℉)
Humidity10%~90% non-condensing
EnclosureWeatherproof design
ChipsetAtheros
RAMVaries by Model
Flash MemoryVaries by Model
Ethernet Ports1

Related product manuals