T10 Installation Notes v1.7
Generic T10 Installation Notes v1.7.doc 12.08.2015
Page 23
Engineering screen 4 (Internal Battery detection)
You must have the internal Battery connected with external power and have had the ignition on
at least once for this screen to function correctly
Led On Internal Battery
Led Off Internal Battery not connected
Engineering screen 5 (Tremble Device detection)
Led Pulses when vehicle/device is shaken indicates trembler operational
Led does NOT pulse when the vehicle is shaken indicates trembler non operational
Engineering screen 6 (Normal Tag Detection)
Not supported in T10
Engineering screen 7 (Authorized Tag Detection)
Not supported in T10
Engineering screen 8 (GPS Satellite Quality)
This screen provides a visual indication as to the quality of the GPS fix. The led is flashed once
for each satellite that the receiver can see where the signal strength (RSSI) is > 35dbm.
The unit is deemed to have a good quality fix if the number of satellites visible above 35dbm is
greater than 4.
Engineering screen 9 (CAN RPM Detection)
This screen displays whether the T10 is detecting the RPM PID signal >100 on the CAN bus.
Led ON CAN RPM PID detected above zero.
Led OFF CAN RPM PID not detected or detected as zero.
Engineering screen 10 (Serial Port 0 RX Activity)
Not supported in T10
Engineering screen 11 (Serial Port 1 RX Activity)
Not supported in T10
Engineering screen 12 (Dallas Button Activity)
Not supported in T10
Engineering screen 13 (Driver Behaviour Dual LED)
Not supported in T10