EasyManua.ls Logo

Trane Technologies 17 Series - User Manual

Trane Technologies 17 Series
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
March 2023 MS-SVN081B-EN
Installers Manual
Split System (R-410A)
17 Series Mini-Split
Inverter System
9,000 Btu/h to 24,000 Btu/h
Models:
HP Outdoor Units: AC Outdoor Units:
4TXK1709A1 4TYK1709A1
4TXK1712A1 4TYK1712A1
4TXK1718A1 4TYK1718A1
4TXK1724A1 4TYK1724A1
HP Indoor Units: AC Indoor Units:
4MXW1709A1 4MYW1709A1
4MXW1712A1 4MYW1712A1
4MXW1718A1 4MYW1718A1
4MXW1724A1 4MYW1724A1
Question and Answer IconNeed help?

Do you have a question about the Trane Technologies 17 Series and is the answer not in the manual?

Overview

This document is an installer's manual for a 17 Series Mini-Split Inverter System, which uses R-410A refrigerant. The system is designed for residential applications and offers cooling and heating capabilities (for heat pump models) with capacities ranging from 9,000 Btu/h to 24,000 Btu/h.

Function Description

The device is a split-system air conditioner/heat pump designed for residential use. It consists of an indoor unit and an outdoor unit, connected by refrigerant piping and electrical wiring. The system provides cooling and, for heat pump models, heating, by circulating R-410A refrigerant. The inverter technology allows for variable compressor speed, which can lead to improved energy efficiency and more precise temperature control compared to traditional fixed-speed systems.

Important Technical Specifications

Models:

  • HP Outdoor Units: 4TXK1709A1, 4TXK1712A1, 4TXK1718A1, 4TXK1724A1
  • AC Outdoor Units: 4TYK1709A1, 4TYK1712A1, 4TYK1718A1, 4TYK1724A1
  • HP Indoor Units: 4MXW1709A1, 4MXW1712A1, 4MXW1718A1, 4MXW1724A1
  • AC Indoor Units: 4MYW1709A1, 4MYW1709A1, 4MYW1712A1, 4MYW1718A1, 4MYW1724A1

Refrigerant: R-410A, which operates at 50 to 70% higher pressures than R-22. Refrigerant Oil: POE (Polyolester) or PVE (Polyvinyl Ether) oil. Power Supply: 208/230V, 60Hz, 1 phase. Each unit requires its own dedicated power supply. Wiring:

  • Interconnecting wires between indoor and outdoor units: at least 14 AWG, 600 volt rated, stranded, four conductor wire, with a maximum length of 230 ft. (70m).
  • Grounding: Class I appliance, must be grounded. Piping Requirements:
  • Liquid pipe: 1/4" inch (all models)
  • Gas pipe: 3/8" (for 9-12K models), 1/2" (for 18K models), 5/8" (for 24K models)
  • Oil traps may be needed for vertical gas pipe lengths exceeding 33 ft (10m) when the outdoor unit is installed lower than the indoor unit, or for every 20 ft (6m) of vertical rise when the outdoor unit is installed higher. Clearance Requirements (Indoor Unit):
  • Space to the ceiling: 6 in. or more
  • Space to the wall (left/right): 6 in. or more
  • Space to the wall (front): 18 in. or more
  • Space to the floor: 66 in. or more
  • Maximum recommended height from floor to bottom of indoor unit: 11.5 ft (3.5 m). Clearance Requirements (Outdoor Unit):
  • Space to the wall (back): >12 in. (305 mm)
  • Space to the wall (sides): >12 in. (305 mm)
  • Space to the wall (front): >79 in. (2000 mm)
  • Space to the wall (top): >20 in. (508 mm)
  • Installation height: at least 1 1/4 inch (31.8mm) above ground or base for drain pipe installation.

Dimensions (Indoor Unit):

  • 09K: W: 31 1/8 in., H: 10 5/8 in., D: 7 7/8 in.
  • 12K: W: 33 1/4 in., H: 11 3/8 in., D: 8 1/4 in.
  • 18K: W: 38 1/4 in., H: 11 13/16 in., D: 8 7/8 in.
  • 24K: W: 42 1/2 in., H: 12 13/16 in., D: 9 11/16 in.

Dimensions (Outdoor Unit):

  • 9K-12K: W: 30 5/8 in., H: 21 1/4 in., D: 12 5/8 in.
  • 18K-24K: W: 38 in., H: 27 5/8 in., D: 15 1/4 in.

Usage Features

  • Remote Control: The system is operated via a remote control (sold separately) for functions like ON/OFF, MODE selection (AUTO, COOL, DRY, FAN, HEAT).
  • Auxiliary Operation: In case of remote controller loss or damage, an auxiliary button on the indoor unit allows for basic ON/OFF operation in auto mode (77°F for cooling, 68°F for heating).
  • Error Codes: The manual provides a list of common error codes (e.g., C5 for System Configuration Malfunction, E1 for High Pressure, E6 for Communication Malfunction) to assist in troubleshooting.

Maintenance Features

  • Regular Checks: Professional personnel should perform regular checks, maintenance, and care to prolong the unit's lifespan.
  • Outdoor Heat Exchanger: Check and clean every two months using a vacuum cleaner with a nylon brush or compressed air. Do not use water.
  • Drain Pipe: Regularly check for clogs to prevent flooding.
  • Indoor Unit Filter: Clean a minimum of every three months, or more often in dusty/smoky environments. Filters can be vacuumed or rinsed with cool, clear water. Warm water (below 115°F/45°C) and mild detergent can be used for very dirty filters. Do not dry filters in direct sunlight or with heat sources to prevent warping or fire hazards.
  • Seasonal Use Checks (Before):
    • Ensure indoor/outdoor unit inlets/outlets are not clogged.
    • Verify secure power and communication cable attachments.
    • Replace wireless remote controller batteries.
    • Clean and securely replace filter screen.
    • For long shutdowns, open the main power switch 8 hours before operation to preheat the compressor.
    • Confirm secure installation of indoor and outdoor units.
    • Contact dealer for any abnormalities.
  • Seasonal Use Maintenance (After):
    • Cut off main power supply.
    • Clean indoor unit filters.
    • Clean dust and debris from indoor and outdoor units.
    • Apply anti-rust paint if rusting occurs.
  • Parts Replacement: Purchase parts from an installing or servicing center or dealer.
  • Leakage Testing: Use nitrogen for leakage testing; never mix oxygen, ethyne (acetylene), or other dangerous gases.

Trane Technologies 17 Series Specifications

General IconGeneral
BrandTrane Technologies
Model17 Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals