SCXF-SVX01T-EN
Digit 25— Industrial Options
A = Protective coating evaporator coil
B = Silver solder
C = Stainless steel screws
D = A and B
E = A and C
F = B and C
G = A, B, and C
0 = none
Digit 26 Drain Pan Type
A = Galvanized sloped
B = Stainless steel sloped
Digit 27 Waterside Economizer
A = Mechanical clean full capacity (4-row)
B = Mechanical clean low capacity (2-row)
C = Chemical clean full capacity (4-row)
D = Chemical clean low capacity (2-row)
0 = None
Digit 28 Ventilation Control
B = Airside econ w/Traq damper, top O/A
C = Airside econ w/ std damper, top O/A
E = Airside econ w/Traq damper & comparative
enthalpy, top O/A
F = Airside econ w/ std damper & comparative
enthalpy, top O/A
H = 2-position damper ventilation interface
J = Airside economizer interface
K = Airside economizer interface w/comparative
enthalpy
Digit 29 Water Piping
D = Left hand basic piping
F = Left hand Intermediate piping
K = Left hand basic w/ flow switch
M = Left hand intermediate w/ flow switch
Digit 30 Condenser Tube Type
A = Standard condenser tubes
B = 90/10 CuNi condenser tubes
Digit 31 Compressor Service Valves
1 = With service valves
0 = None
Digit 32— Miscellaneous System Control
1 = Time clock
2 = Interface for remote HI (IPCB)
3 = Dirty filter switch
4 = 1 and 2
5 = 1 and 3
6 = 2 and 3
7 = 1, 2 and 3
0 = None
Digit 33 Control Interface Options
A = Generic BAS Module; 0-5 Vdc (GBAS)
B = Ventilation Override Module (VOM)
D = Remote Human Interface (RHI)
G = GBAS and VOM
H = GBAS and RHI
J = VOM and RHI
M = GBAS, VOM, and RHI
N = BACnet Communications Interface (BCI)
P = BCI and GBAS
Q = BCI and VOM
R = BCI and RHI
T = BCI and GBAS and VOM
U = BCI and GBAS and RHI
V = BCI and VOM and RHI
W = BCI and GBAS and VOM and RHI
0 = None
1 = Lontalk Comm5 Interface (LCI)
2 = LCI and GBAS
3 = LCI and VOM
4 = LCI and RHI
5 = LCI and GBAS and VOM
6 = LCI and GBAS and RHI
7 = LCI and VOM and RHI
8 = LCI and GBAS and VOM and RHI
Digit 34— Agency
U = UL agency listing
0 = None
Digit 35— Filter Type
1 = 2” T/A w/ 2” rack
2 = 2” med. eff. T/A w/ 2” rack
3 = 4” bolt-on rack w/ 2” med eff. filter
4 = 6” rack w/ 2” construction T/A pre-filter & 4” filter
space
5 = 6” rack w/ 2” med. eff. T/A pre-filter & 4” filter
space
Digit 36— Miscellaneous Control Option
A = Low entering air temp. protect device
(LEATPD)
B = High duct temp t-stat, ship separate
C = Plenum high static switch, ship separate
E = A and B
F = A and C
H = B and C
L = A, B, and C
0 = None
Model Number Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane Technologies IntelliPak Signature SCWF and is the answer not in the manual?

Trane Technologies IntelliPak Signature SCWF Specifications

General IconGeneral
BrandTrane Technologies
ModelIntelliPak Signature SCWF
CategoryFan
LanguageEnglish

Related product manuals