SCXF-SVX01T-EN
11
Model Number Description
Commercial Self-Contained Signature Series
Digit 1 Unit Model
S = Self-Contained
Digit 2 Unit Type
C = Commercial
I = Industrial
Digit 3 Condenser Medium
W = Water-cooled
Digit 4 Development Sequence
F = Signature Series
Digit 5— Refrigerant Circuit Configuration
U = Standard Capacity
V = High Capacity
Digit 6, 7 Unit Nominal Capacity
20 = 20 Tons
22 = 22 Tons
25 = 25 Tons
29 = 29 Tons
32 = 32 Tons
35 = 35 Tons
38 = 38 Tons
42 = 42 Tons
46 = 46 Tons
52 = 52 Tons
58 = 58 Tons
65 = 65 Tons
72 = 72 Tons
80 = 80 Tons
90 = 90 Tons
C0 = 100 Tons
C1 = 110 Tons
Digit 8 Unit Voltage
6 = 200 volt/60 hz/3 ph
4 = 460 volt/60 hz/3 ph
5 = 575 volt/60 hz/3 ph
Digit 9 Air Volume/Temp Control
2 = VFD and supply air temp ctrl
3 = VFD w/ bypass and supply air temp ctrl
4 = Constant volume, zone temp cool only
5 = Constant volume, w/ zone temp heat/cool
6 = Constant volume and supply air temp ctrl
Digit 10, 11 Design Sequence
** = Factory Assigned
Digit 12 Unit Construction
A = Vertical discharge
B = Vertical discharge with double wall
Digit 13— Flexible Horizontal Discharge
Plenum Type
B = STD plenum w/ factory-cut holes
C = Low plenum w/ factory-cut holes
E = Std plenum w/ field-cut holes
F = Low plenum w/ field-cut holes
H = STD plenum double wall w/ field-cut holes
J = Low plenum double wall w/ field-cut holes
K = Extended height plenum w/factory-cut holes,
ship separate
L = STD plenum w/factory-cut holes, ship separate
M = Low plenum w/factory-cut holes, ship separate
N = Extended height plenum w/field-cut holes, ship
separate
P = STD plenum w/field-cut holes, ship separate
R = Low plenum w/field-cut holes, ship separate
T = Extended height double-wall plenum w/ field-
cut holes, ship separate
U = STD double-wall plenum w/field-cut holes, ship
separate
V = Low double-wall plenum w/field-cut holes, ship
separate
W = STD double-wall (perf) plenum w/field-cut
holes (90 to110 ton only)
X = Low double-wall (perf) plenum w/field-cut holes
(90 to 110 ton only)
Y = Extended height double-wall (perf) plenum w/
field-cut holes, ship separate (90 to 110 ton only)
0 = None
Digit 14— Motor Type
2 = ODP motor
4 = TEFC motor
Digit 15, 16 Motor HP
05 = 5 hp
07 = 7.5 hp
10 = 10 hp
15 = 15 hp
20 = 20 hp
25 = 25 hp
30 = 30 hp
40 = 40 hp
50 = 50 hp (460V, 575V only)
60 = 60 hp (90 to 110 ton only)
Digit 17, 18, 19 Fan RPM
040 = 400 rpm
045 = 450 rpm
050 = 500 rpm
052 = 525 rpm
055 = 550 rpm
057 = 575 rpm
060 = 600 rpm
065 = 650 rpm
070 = 700 rpm
075 = 750 rpm
080 = 800 rpm
085 = 850 rpm
090 = 900 rpm
095 = 950 rpm
100 = 1000rpm
105 = 1050 rpm
110 = 1100 rpm
115 = 1150 rpm
120 = 1200 rpm
125 = 1250 rpm
130 = 1300 rpm
135 = 1350 rpm
Digit 20 Unit Isolators
A = Steam coil
B = Hot water coil
C = Electric heat, 1 stage
D = Electric heat, 2 stage
F = Hydronic heat ctrl interface
G = Electric heat ctrl interface
K = Steam coil ship separate, LH
L= Hot water coil ship separate, LH
T = Hot water coil, high capacity, LH
U = Hot water coil, high capacity, LH, ship separate
0 = None
Digit 21 Unit Isolators
A = Isopads
B = Spring isolators
0 = None
Digit 22— Unit Finish
1 = Paint - Slate Gray
Digit 23— Supply Fan Options
0 = Standard fan
1 = Low CFM fan
Digit 24— Unit Connection
1 = Disconnect switch
2 = Terminal block
3 = Dual point power (2 blocks)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane Technologies IntelliPak Signature SCWF and is the answer not in the manual?

Trane Technologies IntelliPak Signature SCWF Specifications

General IconGeneral
BrandTrane Technologies
ModelIntelliPak Signature SCWF
CategoryFan
LanguageEnglish

Related product manuals