Constant Torque Motor
Troubleshooting
Does blower
wheel turn
freely?
Turn off power.
Check set screw
position and motor
bearings. Correct
or replace as
needed.
Check operation
NO
Is ~230 VAC measured
between terminals “L” &
“N” on the motor?
See Figure 1
YES
High voltage should
always be present.
Correct high voltage
wiring.
NO
Is ~24 VAC measured
between the wire connected
to “C” on the motor and the
wire connected to terminal 1
thru 5 on the motor?
See Figure 2
YES
YES
Replace motor.
Check operation
Motor does not run
Turn comfort to
“FAN ON” mode
Is 24VAC measured
from terminal 8(G) to
terminal 9(BL) on the
fan control?
NO
Correct wiring.
Check operation
NO
Replace fan control.
Check operation
YES
This terminal block is located on
the motor. Look for labels below
on the motor side of the
connection.
FIGURE 1
FIGURE 2
NOTE: The fan control has a 90
second “OFF” delay that is
factory set on. To turn this
feature off, turn dip switch to 0
and cycle power to the unit.
CONSTANT TORQUE MOTOR TROUBLESHOOTING FOR GAM5
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor environments for residential applications.
For more information, please visit www.trane.com or www.americanstandardair.com
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are
committed to using environmentally conscious print practices.
© 2020
GAM5-SF-1P-EN 15 April 2020
Supersedes GAM5-SF-1N-EN (September 2018)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane 5 Series and is the answer not in the manual?

Trane 5 Series Specifications

General IconGeneral
RefrigerantR-410A
StagesVariable Speed
ConfigurationHorizontal or Vertical
Cooling Capacity1.5 to 5 Tons
AirflowUp to 2000 CFM
Voltage208/230V

Related product manuals